The HR-02-230V is a premium 16-zone wired underfloor heating and cooling wiring centre, specifically engineered for European heat pump systems. Operating on a standard 230V system (with 24V options available), it seamlessly manages thermal actuators, circulation pumps, and heat pump changeover signals.
Modern European heating systems, particularly Air Source Heat Pumps (ASHP) and Ground Source Heat Pumps (GSHP), require advanced control logic to maximize energy efficiency and comfort. This premium 230V wired wiring centre is the ultimate nerve centre for your hydronic system, ensuring perfectly balanced room temperatures while strictly adhering to European safety standards for wet environments. Deploying a reliable water underfloor heating thermostat alongside this controller guarantees full thermal comfort all year round.

1. Heating & Cooling Changeover
Modern heat pumps provide both winter heating and summer cooling. This 230V wiring centre automatically receives the changeover signal from the heat pump or master thermostat, seamlessly shifting the entire system's operating logic between underfloor heating and underfloor cooling modes.
2. Humidity & Dew Point Protection (Anti-Condensation)
When operating in cooling mode, high indoor humidity can lead to dangerous floor condensation. By integrating with a humidity/dew point sensor, the controller constantly monitors the environmental conditions. If the floor temperature drops near the dew point, it instantly closes the specific zone's actuators, ensuring absolute safety for premium wood or laminate floors.
3. PWM Automatic Hydraulic Balancing
To qualify for European heat pump subsidies (e.g., BAFA in Germany), precise hydraulic balancing is mandatory. The built-in PWM (Pulse Width Modulation) algorithm automatically adjusts the opening time of each circuit's valve, effectively eliminating the need for manual flow meter adjustments and maximizing energy savings.

Our HR-02-230V controller is engineered to meet the highest international standards for safety, reliability, and environmental responsibility:
| Model Name | 230V Underfloor Heating & Cooling Wiring Centre |
|---|---|
| Power Supply | 230Vac |
| Actuator Output | 230Vac (Controls up to 8/16 Zones) |
| Heat Pump / Boiler Output | Voltage-free (Dry Contact) |
| Heating & Cooling Mode | Supported (Via external changeover signal) |
| Dew Point Input | Yes (For anti-condensation protection) |
| Hydraulic Balancing | PWM (Pulse Width Modulation) Algorithm |
| Certificates | CE (RED/EMC/LVD), UKCA, FCC, ETL Listed, RoHS, REACH |


A: No, it does not interfere with the heat pump's complex inverter mainboard or refrigerant cycle. Instead, it acts as an intelligent hydronic bridge. It collects demand signals from room thermostats and sends a safe "Volt-free" (dry contact) trigger to the heat pump, instructing it to produce hot or cold water. Simultaneously, it opens the correct manifold actuators and turns on the external circulation pump.
A: The controller is fully compatible with standard 230Vac thermoelectric actuators. It supports both Normally Closed (NC) and Normally Open (NO) actuators, which are widely used in European manifold setups.
A: Yes, it features a dedicated 230V relay output for the underfloor heating manifold's circulating pump. The pump will only be activated when there is a clear demand from at least one heating or cooling zone, preventing energy waste.
A: Yes, it is specifically designed for reversible heat pumps. It accepts a global changeover signal from the heat pump or a master thermostat to automatically switch all connected room thermostats and thermal actuators between heating and cooling modes seamlessly.
A: Condensation occurs during underfloor cooling if the indoor humidity is too high. By connecting a humidity/dew point sensor, the controller constantly calculates the condensation risk based on room conditions. If the floor temperature approaches the dew point, it shuts off the water flow to the affected zones, protecting your premium wooden flooring from water damage.