Multi-zones Wired Wiring Centres
Home / Multi-zones Wired Wiring Centres / 230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps
230V Underfloor Heating Wiring Centre for European Heat Pumps

230V Underfloor Heating Wiring Centre for European Heat Pumps

The HR-02-230V is a premium 16-zone wired underfloor heating and cooling wiring centre, specifically engineered for European heat pump systems. Operating on a standard 230V system (with 24V options available), it seamlessly manages thermal actuators, circulation pumps, and heat pump changeover signals.

Core Features for Heat Pump Systems:

  • Heating & Cooling: Optimized for Air Source (ASHP) & Ground Source Heat Pumps.
  • 230V Standard Operation: Universal compatibility with European 230Vac actuators (24V option available for specific safety codes).
  • Dew Point Protection: Integrated anti-condensation sensor input for floor safety during cooling.
  • PWM Balancing: Smart hydraulic balancing algorithm for maximum energy savings.
  • Zone Capacity: Controls up to 16 independent zones (max. 5 actuators per zone).
  • System Synergy: Voltage-free relay output for direct boiler or heat pump triggering.

230V Underfloor Heating & Cooling Wiring Centre for Heat Pumps

Modern European heating systems, particularly Air Source Heat Pumps (ASHP) and Ground Source Heat Pumps (GSHP), require advanced control logic to maximize energy efficiency and comfort. This premium 230V wired wiring centre is the ultimate nerve centre for your hydronic system, ensuring perfectly balanced room temperatures while strictly adhering to European safety standards for wet environments. Deploying a reliable water underfloor heating thermostat alongside this controller guarantees full thermal comfort all year round.

230V 16-zone underfloor heating and cooling wiring centre main view with heat pump features

Advanced Heat Pump Integration: The 3 Core Technologies

1. Heating & Cooling Changeover
Modern heat pumps provide both winter heating and summer cooling. This 230V wiring centre automatically receives the changeover signal from the heat pump or master thermostat, seamlessly shifting the entire system's operating logic between underfloor heating and underfloor cooling modes.

2. Humidity & Dew Point Protection (Anti-Condensation)
When operating in cooling mode, high indoor humidity can lead to dangerous floor condensation. By integrating with a humidity/dew point sensor, the controller constantly monitors the environmental conditions. If the floor temperature drops near the dew point, it instantly closes the specific zone's actuators, ensuring absolute safety for premium wood or laminate floors.

3. PWM Automatic Hydraulic Balancing
To qualify for European heat pump subsidies (e.g., BAFA in Germany), precise hydraulic balancing is mandatory. The built-in PWM (Pulse Width Modulation) algorithm automatically adjusts the opening time of each circuit's valve, effectively eliminating the need for manual flow meter adjustments and maximizing energy savings.

European heat pump underfloor heating controller system application with manifold

Certifications & Global Compliance

Our HR-02-230V controller is engineered to meet the highest international standards for safety, reliability, and environmental responsibility:

  • Safety & EMC: Fully compliant with CE (RED/LVD/EMC), UKCA, FCC, and ETL Listed standards.
  • Environmental: Certified by RoHS and REACH, ensuring lead-free and eco-friendly manufacturing.
  • Quality Management: Produced in an ISO 9001:2015 and ISO 14001:2015 certified facility.

230V wiring centre certifications: CE, UKCA, FCC, ETL, RoHS, ISO9001

Technical Parameters

Model Name 230V Underfloor Heating & Cooling Wiring Centre
Power Supply 230Vac
Actuator Output 230Vac (Controls up to 8/16 Zones)
Heat Pump / Boiler Output Voltage-free (Dry Contact)
Heating & Cooling Mode Supported (Via external changeover signal)
Dew Point Input Yes (For anti-condensation protection)
Hydraulic Balancing PWM (Pulse Width Modulation) Algorithm
Certificates CE (RED/EMC/LVD), UKCA, FCC, ETL Listed, RoHS, REACH

Product Dimensions

24V Heat Pump Wiring Centre Dimensions

Installation Guide

24V Underfloor Heating Controller DIN Rail Installation

Frequently Asked Questions (FAQ)

Q1: Does this wiring centre directly control the heat pump's internal mainboard or compressor?

A: No, it does not interfere with the heat pump's complex inverter mainboard or refrigerant cycle. Instead, it acts as an intelligent hydronic bridge. It collects demand signals from room thermostats and sends a safe "Volt-free" (dry contact) trigger to the heat pump, instructing it to produce hot or cold water. Simultaneously, it opens the correct manifold actuators and turns on the external circulation pump.

Q2: What type of thermal actuators are compatible with this 230V controller?

A: The controller is fully compatible with standard 230Vac thermoelectric actuators. It supports both Normally Closed (NC) and Normally Open (NO) actuators, which are widely used in European manifold setups.

Q3: Can I connect an external circulating pump directly to this wiring centre?

A: Yes, it features a dedicated 230V relay output for the underfloor heating manifold's circulating pump. The pump will only be activated when there is a clear demand from at least one heating or cooling zone, preventing energy waste.

Q4: Does this wiring centre support automatic heating and cooling changeover?

A: Yes, it is specifically designed for reversible heat pumps. It accepts a global changeover signal from the heat pump or a master thermostat to automatically switch all connected room thermostats and thermal actuators between heating and cooling modes seamlessly.

Q5: How does the Humidity and Dew Point Protection feature work?

A: Condensation occurs during underfloor cooling if the indoor humidity is too high. By connecting a humidity/dew point sensor, the controller constantly calculates the condensation risk based on room conditions. If the floor temperature approaches the dew point, it shuts off the water flow to the affected zones, protecting your premium wooden flooring from water damage.

Leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Related Products
8 zone underfloor heating wiring centre din rail installation

The HR-02-230V is a premium 16-zone wired underfloor heating and cooling wiring centre, specifically engineered for European heat pump systems. Operating on a standard 230V system (with 24V options available), it seamlessly manages thermal actuators, circulation pumps, and heat pump changeover signals. Core Features for Heat Pump Systems: Heating & Cooling: Optimized for Air Source (ASHP) & Ground Source Heat Pumps. 230V Standard Operation: Universal compatibility with European 230Vac actuators (24V option available for specific safety codes). Dew Point Protection: Integrated anti-condensation sensor input for floor safety during cooling. PWM Balancing: Smart hydraulic balancing algorithm for maximum energy savings. Zone Capacity: Controls up to 16 independent zones (max. 5 actuators per zone). System Synergy: Voltage-free relay output for direct boiler or heat pump triggering.

Learn More
230V 16-zone underfloor heating and cooling wiring centre main view with heat pump features

The HR-02-230V is a premium 16-zone wired underfloor heating and cooling wiring centre, specifically engineered for European heat pump systems. Operating on a standard 230V system (with 24V options available), it seamlessly manages thermal actuators, circulation pumps, and heat pump changeover signals. Core Features for Heat Pump Systems: Heating & Cooling: Optimized for Air Source (ASHP) & Ground Source Heat Pumps. 230V Standard Operation: Universal compatibility with European 230Vac actuators (24V option available for specific safety codes). Dew Point Protection: Integrated anti-condensation sensor input for floor safety during cooling. PWM Balancing: Smart hydraulic balancing algorithm for maximum energy savings. Zone Capacity: Controls up to 16 independent zones (max. 5 actuators per zone). System Synergy: Voltage-free relay output for direct boiler or heat pump triggering.

Learn More