Etop is a leading manufacturer of HVAC thermostat and smart home thermostat in China. Founded in 2003, we have been designing and producing various smart wifi thermostat for energy efficient heating and cooling temperature controller market, such as boiler heating wifi thermostat, water underfloor heating wifi thermostat, electric underfloor heating wifi thermostat, wifi smart radiator valve thermostat, modbus fcu thermostat, wifi heat pump thermostat etc.
To save more energy, clients can adjust the thermostat in the parameter setting. Below is basic for UFH thermostat. If you wanna know more about ETOP thermostat technical data,feel free to contact us. info@etopcontrols.com
Feature 01 – thermostat with temperature calibration. This feature used to calibrate the room temperature when need. For example, if actual room temperature 21.5°C, but thermostat shows 23°C, then you can set this value to -1.5 to calibrate.
Feature 02/03– thermostat with max and min temperature setpoint. Temperature Max.& Min. Limit: This function allows you to limit the use of the up and down temperature by pressing +/- buttons.
Menu 05 - thermostat with frost protection function. Low Temperature Protection: This is the temperature maintained when the thermostat is in Frost Mode. If room temperature below 5°C(Settable), thermostat will turn on heating device till room temperature arrive 5°C(Settable).
Menu 09 - thermostat with hysteresis. Switching Differential: This function allows you to increase the switching differential of the thermostat. The default is 0°C which means that with a set temperature of 20°C, the thermostat will switch the heating on at 19.5°C and off at 20.5°C. With a 0.5°C differential, the heating will switch on at 19°C and off at 21°C.
Menu 11– thermostat with child lock. This feature used to lock the keys. When lock, you can long press SET button 5 seconds to unlock.
Menu 12- thermostat with open window detection function.This function allows you to save energy. When enable Open Window Detection function, the system will automatically stop heating when it detects a sudden drop of room temperature (2°C in 15 minutes as default). This is normally caused when a window or door is opened without turning off the heating device.
The device will return to the previous mode of operation after 30mins, then window disappear. Press any button will exit OWD function during the heating off period.